Z-Score Expert System

SKU zscore_expert
Stock
Wishlist

Create Wishlist

Enjoy all of the benefits of our most complete neurofeedback system ever. This system enhances the benefi ts derived from EEG & Z-Score neurofeedback with heart rate variability (HRV) & biofeedback relaxation training. In addition, it extends the Z-Score intermediate System with the ability to train EEG & Physiology simultaneously. Included
in the system are the ProComp ∞, the Z-Score 6 Suite, the 360 Suite, 4 EEG-Z impedance testing sensors, the Skin Conductance & Temperature sensors, along with the Blood Volume Pulse, Respiration & MyoScan-Pro sensors. The most complete training system for any neurofeedback practitioner.

Our expert Z-Score System integrates our most advanced normative neurofeedback training modality with peripheral biofeedback. The Z-Score Advanced System is our complete & easy to use 4 channel neurofeedback package. It is the most complete training system for any neurofeedback practitioner.

With this system you can:

  • Run 2 or 4 Channel Z-Score trainings & assessments
  • Focus your Z-Score training with Connectivity, Power & Power Ratio indexes
  • Select any of 248 Z-Score metrics for targeted 2 or 4-Channel training
  • Use all standard EEG protocols (SMR, Alpha-Theta, Theta-Beta, Coherence, …)
  • Train with Heart Rate Variability, EMG, Skin Conductance & Temperature
  • Artifact & analyse your sessions with Biograph Infiniti
  • Monitor progress with trend reports

Complete System Includes:

Encoder

T7500M - ProComp Infiniti Encoder - 8 Channel

The ProComp Infiniti™ is an 8 channel, multi-modality encoder which connects to your Windows desktop or laptop PC via a USB port and offers all the power and flexibility you need for real-time, computerized biofeedback and data acquisition in any clinical or research setting. It can also store data on a Compact Flash memory card, for uploading later to the PC, or use an optional long-range compact flash telemetry module to offer a wide range of recording options.

A full selection of physiological sensors, including EKG and blood volume pulse (heart rate), respiration belt, EMG (muscle tension), skin conductance, temperature, brainwaves, and forehead temperature allows you to take full advantage of all the tools provided by the 360 Suite.

The first two sensor channels provide ultimate signal fidelity (2048 samples per second) for viewing RAW EEG, EMG, EKG, and BVP signals. The remaining six channels (256 samples/sec) can be used with any combination of sensors, including EEG, EKG, skin conductance, heart rate, blood volume pulse, respiration and passive infrared HEG. ProComp Infiniti™ offers internal, user-activated calibration to ensure that you can always obtain the highest quality signal, without the costly downtime associated with factory re-calibration.

In short, the ProComp Infiniti covers the full range of objective physiological signals used in clinical observation and biofeedback.

Software

BioGraph Infiniti Software

BioGraph Infiniti Software is the core of all our Biofeedback and Psychophysiology products. It provides a multimedia rich graphical experience, while capturing and analyzing raw data. It also includes all the features and functions required to run our specialized application Suites.

Suites

Z-Score 6 Suite

This Z-Score 6 Suite will allow the user to perform z-score assessment and training with in two ways: using the z-score value itself, or using a metric, called the z-score index, which is indicative of the state of a group of z-scores.

The z-score index tells us at a given moment how many of a pre-selected group of z-scores are within a certain threshold range. This threshold range is user-definable and can be modified on-the-fly. The user also has the choice of which z-scores to include, and can do so easily at any time during the session. The suite includes 4 pre-set z-score indices.

These are:

  • z-score index (includes all z-scores)
  • z-score powers index (includes only the power z-scores, for all channels)
  • z-score power ratios index (includes only the power ratio z-scores, for all channels)
  • z-score connectivity index (includes only the coherence, phase and amplitude asymmetry z-scores, for all channel pairs)

360 Suite

The suite combines classic physiological biofeedback (arousal and peripheral temperature) with heart rate variability training (HRV) and neurofeedback protocols (EEG biofeedback) into one integrated package.

The suite’s broad selection of tools includes:

  • Specialized physiological assessments
  • Self-regulation training screens
  • Biofeedback assisted relaxation therapy sessions

Suite Add-ons

SA7908 - Z-Score Biofeedback Add-On CD (4-Channel)

Benefits of Z Score Biofeedback Add-on:

  • Add the power of real-time z-scores to BioGraph Infiniti. Compare 2 or 4-channel EEG to NeuroGuide’s normative database automatically. Metrics include coherence, phase, amplitude asymmetry, relative power, absolute power and power ratios for eight different frequency bands.
  • Simple measure of progress based on combined z-score metric and in-session real-time trending.
  • Simplifies training as strategy is always towards norm – instead of an arbitrary value that may be difficult to determine.
  • Can also be used in pre- and post- assessment of general connectivity training. In this approach, training can be directly on the metric, such as coherence, for example, whereas post-session analysis can include the z-score deviations of coherence from norm, all within BioGraph Infiniti.
  • Faster results: in both the above cases, multiple operations are combined as the need to export data from BioGraph and send away for z-score assessments is eliminated. The power is all in one place, and the strategy is always the same: train towards norm.

Sensors

T9305Z - EEG-Z™ Sensor (x4)

EEG-Z is a pre-amplified electroencephalograph sensor with built in impedance checking. Get the ultimate hook up every time with this sensor as it monitors skin impedance (both the reactive and resistive elements) and sensor connection.

SA9309M - Skin Conductance Sensor

The Skin Conductance sensor measures the galvanic skin response, and is normally connected to the fingers or toes. Includes two finger bands.

SA9310M - Temperature Sensor

The Temperature sensor measures skin surface temperature between 10°C – 45°C (50°F - 115°F ). It is supplied with a self adhering band for easy finger placement.

SA9311M - Respiration Sensor

Respiration Sensor includes a sensitive and repeatable girth sensor using an easy fitting high durability latex rubber band fixed with self-adhering belt for monitoring respiration rate, waveform and amplitude. Can be worn either thoracically or abdominally, over clothing.

SA9308M - Blood Volume Pulse (BVP)

BVP sensor is a blood volume pulse detection sensor (otherwise known as a PPG sensor) housed in a small finger worn package, to measure heart rate & provide BVP amplitude, BVP waveform, HR and Heart rate variability feedback.

T9401M-60 - EMG MyoScan-Pro Sensor

EMG MyoScan Pro is a pre-amplified surface electromyography sensor used with the ProComp Infiniti channels C – H for RMS sEMG. Features a range switch in the sensor head to change filter settings between 0 – 400 µV Narrow filter, 0 – 400 µV Wide filter, 0 – 1600 µV Wide filter with 0.1 µV sensitivity. Compatible with Triode electrodes or extender cables for wider placement of electrodes.

Electrodes

T3402M - Triode Electrodes

Triode™ electrodes (100pcs), with standard 2cm spacing of silver silver chloride electrodes, backed with nickel plated brass snaps to prevent corrosion when connected to pre-amplifiers for extended periods.

Accessories

T8761 - TT-EEG 4 Channels Connectivity Kit

TT-EEG 4 Channel Connectivity Kit 24in, 61cm (requires four T8750)


Documents
Downloads
None

USA Federal law restricts this device to sale by or on the order of a physician or any other practitioner licensed by the law of the state in which he or she practices to use or order the use of this device.