Neurofeedback

Electrodes

content divider
  • Triode Electrode(A) T3402M - TriodeTM electrode, with standard 2cm spacing of silver silver chloride electrodes, backed with nickel plated brass snaps to prevent corrosion when connected to pre-amplifiers for extended periods.
  • (B) T3425 - UniGel electrodes, pre gelled single electrodes, or sensitive placements on dry skin. It can be used in place of T3404 single strip electrodes.

T8750TT-EEG Monopolar Bipolar Kit with DIN Cable - T8750
Includes two gold cup cables and two gold ear clip cables, as well as our DIN extender cable.

  • Create a single monopolar channel with one cup and two ear clips, or a single bipolar channel with two cups and one ear clip.
  • For use with the EEG Flex/Pro and EEG-Z sensors.

T8751TT-EEG Monopolar Bipolar Kit without DIN Cable - T8751
Same as T8750 with the DIN extender cable excluded.

  • For our users who have previously purchased the DIN extender cable.

TT-EEGTT-EEG Linked Ears Kit
Includes the necessary cables to add a linked ear reference to the monopolar/bipolar kit.

  • Used in combination with the TT-EEG Monopolar/Bipolar Electrode Kit.
  • Add a linked ear reference to the monopolarconfiguration and choose between ear clip or cup electrode active ground.

T8760TT-EEG 2 Channel Connectivity Kit (requires two T8750) - T8760
Includes the necessary cables to measure two channels with common reference and ground.

  • Used in combination with two TT-EEG Monopolar/Bipolar Electrode kits.
  • Connect one or two monopolar or bipolar channels, with the same reference for both channels.
  • Choose between linked ear or single ear reference, and between ear clip or cup electrode active ground.

content dividerTT-EEG 4 Channel Connectivity Kit (requires four T8750) - T8761
Includes the necessary cables to measure up to four channels with common reference and ground.

  • Our most flexible TT-EEG kit. Used in combination with four TT-EEG Monopolar/Bipolar Electrode kits.
  • Connect one, two, three or four monopolar or bipolar channels, with the same reference for all channels.
  • Choose between linked ear or single ear reference, and between ear clip or cup electrode active ground.

content dividerEEG DIN Extender Cable - T8740
Connects to client via replaceable electrodes. Enabling monopolar or bipolar connections it is the most versatile option. Electrodes purchased separately.