+1(800) 361-3651
Monday - Friday 9am-5pm EST/EDT

HRV Intermediate System

Quick Overview

Go one step further with our HRV Intermediate System which adds the ability to record key peripheral physiology with the HRV measures. The system comes with the 5-channel ProComp 5 and all the software tools you need to widen your heart rate variability biofeedback capabilities.

HRV_Intermediate
$4,245.00
OR

Details

Heart rate variability is created by the interplay of many physiological processes but most HRV systems on the market only monitor heart rate. The HRV Intermediate System gives you a much broader perspective on the physiology of HRV, with the mid-range ProComp 5 encoder and physiological sensors, which include EKG, respiration skin conductance and peripheral temperature. BioGraph Infiniti and the Physiology Suite complete the system to give you the largest variety of HRV biofeedback options.

Using BioGraph Infiniti and the Physiology Suite, you can:

  • Do biofeedback sessions with many standard HRV metrics, including SDRR, VLF, LF & HF Power and HR max-min.
  • Use the resonance frequency detection screen to determine the optimal breathing rate to maximise variability.
  • Teach you clients how slow regular breathing can help them relax effectively.
  • Review biofeedback sessions and observe how various physiological measures responded to your training.

Complete System Includes:

ProComp5 Infiniti Encoder - 5 Channel

ProComp5 The ProComp5 Infiniti™ device is housed in an ergonomically-designed case and requires only a USB port to connect to your Windows desktop or laptop PC. It can also store data on a Compact Flash memory card, for uploading later to the PC, or use an optional long-range compact flash telemetry module to offer a wide range of recording options.

The two EEG Z sensors are specialised preamplifiers which come with integrated impedance checking functionality to help you record brainwaves with optimal quality. Using two sensors allows you to do bilateral EEG training protocols and start exploring connectivity metrics, such as coherence.

Unlike competitive equipment, all channels can be used with any combination of sensors, including EEG, EKG, RMS SEMG, Skin Conductance, heart rate, blood volume pulse, respiration, goniometry, force, Inclinometer, Torsiometer and Voltage Input.



Learn More

BioGraph Infiniti Software

BioGraph Infiniti Software is the core of all our Biofeedback and Psychophysiology products. It provides a multimedia rich graphical experience, while capturing and analyzing raw data. It also includes all the features and functions required to run our specialized application Suites.

New Look & Feel

Binaural BeatVersion 6.0’s many enhancements will please many current and new users. BioGraph’s menus were reorganized to group functionality in logical sets. Many dialog boxes were simplified and the flow of a number of functional sequences (start session, review sessions, export data, etc) were streamlined to minimize mouse clicks and facilitate user decisions. A number of automatic default settings were implemented such as: Notch filter frequency, default temperature units and page size format. New easy screen resize function fits all monitors and is saved for the next session.



Learn More

Physiology Suite

The Physiology Suite includes all the tools you need for multi-modality physiological assessments and over 80 display screens for training with standard physiological sensors including heart rate with EKG or blood volume pulse (BVP), electromyography (EMG), skin conductance, temperature and respiration. Using the Physiology suite, you can train self-regulation with physiological biofeedback protocols that include relaxation with EMG, temperature or skin conductance, heart rate variability with respiration and EKG or BVP and abdominal/thoracic breathing. The suite also features a full-length relaxation exercise script with a recorded audio track guiding the client through deep relaxation and progressive recovery.

For your clinical assessments and follow-ups, the suite incorporates pre and post-training baseline assessment scripts and a 7-activity Stress Assessment script which takes the client through three cycles of stress induction and relaxation steps, including color words, math task and stressful event recall. Using the stress assessment script, you can rapidly identify any hyper- or hypo-reactivity in any of the recorded modalities.

Physiology Suite features

  • A skin-conductance driven relaxation script with audio induction track
  • A full range of heart rate variability training screens
  • Simple feedback screens with auto or manual thresholds
  • Single and dual-monitor display screens
  • Real-time epoch statistics for instant trend graphing



Learn More

Respiration Sensor

Respiration Sensor Respiration Sensor includes a sensitive and repeatable girth sensor using an easy fitting high durability latex rubber band fixed with self-adhering belt for monitoring respiration rate, waveform and amplitude. Can be worn either thoracically or abdominally, over clothing.



Learn More

Skin Conductance Sensor

ProComp5 Skin Conductance sensor measures the conductance across the skin, and is normally connected to the fingers or toes. Supplied with two finger bands.



Learn More

Temperature Sensor

temperature sensor Temperature sensor measures skin surface temperature between 10°C – 45°C (50°F - 115°F ). It is supplied with a self adhering band for easy finger placement.



Learn More

Blood Volume Pulse (BVP) Sensor

Blood Volume Pulse Sensor BVP sensor is a blood volume pulse detection sensor (otherwise known as a PPG sensor) housed in a small finger worn package, to measure heart rate & provide BVP amplitude, BVP waveform, HR and Heart rate variability feedback.



Learn More

 



USA Federal law restricts this device to sale by or on the order of a physician or any other practitioner licensed by the law of the state in which he or she practices to use or order the use of this device.

Additional Information

SKU HRV_Intermediate
Downloads No
Documentation

Policy Regarding Returns of Software and Suites

BioGraph 6.0 Flyer

BioGraph 6.0 Manual

EEG & Physiology Suite Flyer

EEG Suite Manual

Basics of Heart Rate Variability

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.

Copyright 2016 - Thought Technology Ltd. All rights reserved. - MAR1044